TRAVEL control bit is set for the trolley or hoist. When "F2-Start" is used, recording is performed
immediately and permanently. The "View diagram" window closes automatically when the "F2-
Start" or "F4-Start Trigger" button is operated.
The recording phase can be monitored online on the screen and starts with a display of the
signal flows over time. It is possible to switch to the x/y diagram at any time. The recording is
ended using the "F3-Stop" button (see screenshot below).
Figure 8-23
During recording, the main values are displayed at a faster sampling rate than the rate defined
in the setting. When the "F3-Stop" button is operated, the signals are loaded with the set
sampling rate.
The "File" and "Reload last chart" menu items can be used to load the most recent recording
at a specified sampling rate.
To improve clarity, the number of parameters to be recorded can be restricted. This is done on
the "Main values," "Input bits," and "Output bits" tabs of the "View diagram" window.
The following settings can be defined on the "Main values" tab (see screenshot below):
● Values to be transferred
Activate all interesting parameters to be displayed as curves in the upper half.
● All ON
Select all parameters
● All OFF
Select no parameters
Figure 8-24
The following settings can be defined on the "Input bits" and "Output bits" tabs:
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
SIMOCRANE CeCOMM commissioning and diagnostic program
Diagram function, ending the recording
Diagram function, F2-Start, Main values tab
8.7 Diagram - trace function
291