Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 378

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Alarm, error, and system messages
10.5 Error messages
E6 (Bit 1) Invalid mode, hoist
An operating mode that is not available has been selected or several operating modes have
been selected at the same time. The error message also appears when semi-automatic mode
(SAM) has been selected for only one drive.
Error type:
Remedy:
E7 (Bit 9) Invalid mode at the limit switch, trolley
A limit switch has responded in the SAM and POS modes. Braking is performed with maximum
deceleration in both directions.
Error type:
Remedy:
E8 (Bit 9) Invalid mode at the limit switch, hoist
A limit switch has responded in the SAM and POS modes. Braking is performed with maximum
deceleration in both directions.
Error type:
Remedy:
E9 (Bit -/-) Hoisting height has jumped
The hoist position has changed abruptly to an impermissible height (> 10 m).
Error type:
Remedy:
E10 (Bit 0) Invalid parameter file
An error has occurred while loading the parameter files. Parameter files are missing or are
faulty. The relevant parameter set will be set to default values. The error value (1-4) specifies
which parameter set could not be loaded.
Error type:
Remedy:
E11 (Bit -/-) Invalid parameter value
An invalid value [X*10000+P] was found when loading parameter P in parameter set (1-4) from
file parX.txt (X:0-3). The value has been set to the default value. The error is only reset after the
parameter files have been loaded successfully.
Error type:
Remedy:
378
Error
Check the PLC program; set only one operating mode bit per drive
Error
Exit the limit switch range in MAN mode
Error
Exit the limit switch range in MAN mode
Alarm
Reference hoisting height encoder again
Error
Check parameters in the parameter menu, save and reload
Alarm
Check parameters in the parameter menu, save and reload
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics