Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 386

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Alarm, error, and system messages
10.5 Error messages
Error type:
Remedy:
E62 (Bit 6) Start POS or SAM with excessive oscillation
Travel has been started in POS or SAM mode at a time when the oscillation was excessive.
The error bit is set if the oscillation is greater than the value set in P156.
The error is triggered only at the start of travel, i.e. when the TRAVEL control bit is set.
The error remains active during travel in POS or SAM mode and is not reset again until the
travel operation is completed, i.e. after the TRAVEL control bit has been reset.
In the following scenarios, the error is not set or is immediately reset:
● The POS control bit or the SAM control bit is not set.
● The TRAVEL control bit is not set.
● The SC_ON control bit is not set.
This error has no effect on the operating behavior. The user is free to choose the error
response. If you want the response to be "braking at maximum acceleration", you can program
this error bit in the higher-level control system to reset the TRAVEL control bit.
Error type:
Remedy:
E63 (Bit 10) Damping factor reduced, trolley
The damping factor for the trolley has been reduced for stability reasons.
This is done in the following cases:
● The oscillation is too high and the damping factor is reduced to < P159.
● Increased oscillation has been detected.
● The oscillation cannot be eliminated during stopping.
Error type:
Remedy:
E64 (Bit 27) Velocity too high before blocked region
The velocity before a blocked region is too high to permit timely deceleration when switching to
SAM. The sway control system does not initiate a stop as a result of this error.
A reaction must come from the higher-level control system.
Error type:
Remedy:
386
Error
Check parameters.
Error
Eliminate sway manually. Check parameter P156
Error
Eliminate sway manually.
Error
Take deceleration distance into account or start at low velocity.
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics

Table of Contents