Elements And Functionality Of The Diagram User Interface - Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

8.7.2

Elements and functionality of the diagram user interface

The user interface displays the signal flows with a legend on the right-hand side. Individual
values or all values can be selected in this legend. If you move the mouse pointer over the
curves, the current x and y values will be displayed dynamically in the corners, as shown in the
following figure.
Figure 8-27
Because of the size relationships, the velocity values and the pendulum deflection are located
on the left-hand axis in the distance/velocity-time curve. The curves for the distance are located
on the right-hand axis. The signals are displayed only as numeric values without unit so that the
user can arbitrarily assign the curves to the axes. The default assignment of the signals to the
axes and the associated unit are listed in the following table.
Values to be transferred
Table 8-2
Analog signals, trolley
Short name
Meaning
V_SET [TR]
Trolley set velocity specified by the master switch
V_REF [TR]
Trolley set velocity using the set ramps
V_POS [TR]
Trolley output velocity computed by the calculation model
V_ACT [TR]
Actual trolley velocity
DEL_MODEL [TR]
Pendulum deflection calculated by the model (distance of the reflector from its home po‐
sition)
DEL_CAMERA
Pendulum deflection detected by the camera measuring system (distance of the reflector
[TR]
from its home position)
S_REF [TR]
Set position, trolley
S_ACT [TR]
Actual position, trolley
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
SIMOCRANE CeCOMM commissioning and diagnostic program
Diagram function, display elements
8.7 Diagram - trace function
Unit
mm/s
mm/s
mm/s
mm/s
mm
mm
mm
mm
293