11.9 TLS
P312 Time window camera fault detection TLS
Period during which criterion "internal deactivation of skew-damping function" must be fulfilled
with poor camera signal
Default: 30 [s]
Access code: 0
P313 Camera fault trigger threshold
The Camera_OK status bit must be set at least for this percentage (trigger threshold) of all
cycles within time window P312. Otherwise, error E69 is triggered.
Default: 90 [%]
Access code: 0
P314 Threshold value for E75
Error E75 is set as soon as the maximum value of the skew oscillation (camera or model) is
greater than parameter P314 (see the description for E75).
Default: 1500 [cgr]
Access code: 0
P317 Oscillation amplitude for error reset E75
If the oscillation amplitude falls below P317, error E75 is set after time period P318 (see also
the description of E75).
Default: 300 [cgr]
Access code: 0
P318 Time period from which error E75 is reset
If the oscillation amplitude falls below P317, error E75 is set after time period P318 (see also
the description of E75).
Default: 20 [s]
Access code: 0
P320 Release skew drive
Skew-damping is implemented with the electric skew drive rather than the cylinders.
● 0: Skew damping via electric drive off
● 1: Skew damping via electric drive on
430
min: 0 [s]
min: 0 [%]
min: 0 [cgr]
min: 0 [cgr]
min: 0 [s]
max: 1000 [s]
max: 100 [%]
max: 9000 [cgr]
max: 9000 [cgr]
max: 1000 [s]
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics

Table of Contents