Error In The Limit Or Prelimit Switch Area - Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

E12 (Bit -/-) Corrupted language file
Lines that are too long or cannot be displayed have been detected during loading of the
language file Sprache0.txt or Sprache1.txt.
Error values:
Error type:
Remedy:
E13 – E19 reserved
10.5.3.4

Error in the limit or prelimit switch area

E20 (Bit -/-) Forward prelimit switch switches incorrectly, trolley
The prelimit switch in the forward direction became active for negative velocity or inactive for
positive velocity.
Error type:
Remedy:
E21 (Bit -/-) Upper prelimit switch switches incorrectly, hoist
The prelimit switch in the forward direction became active for negative velocity or inactive for
positive velocity.
Error type:
Remedy:
E22 (Bit -/-) Backward prelimit switch switches incorrectly, trolley
The prelimit switch in the backward direction became active for positive velocity or inactive for
negative velocity.
Error type:
Remedy:
E23 (Bit -/-) Lower prelimit switch switches incorrectly, hoist
The prelimit switch in the backward direction became active for positive velocity or inactive for
negative velocity.
Error type:
Remedy:
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
0...199 – Parameter texts
200...300 – Error texts
300...400 – Commissioning texts
Alarm
Load a correct language file
Alarm
Exchange forward and backward prelimit switch signals
Alarm
Exchange upper and lower prelimit switch signals
Alarm
Exchange forward and backward prelimit switch signals
Alarm
Exchange upper and lower prelimit switch signals
Alarm, error, and system messages
10.5 Error messages