Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 55

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Connections
The inputs of the DCC block are connected via unit-global variables of the MCC source file
"AddOn" to the outputs of the "FB_CommonPLCToAddOn" block. The DCC block outputs are
interconnected with the inputs of the "FB_CommonAddOnToPLC" block using unit-global
variables.
Table 3-17
DCC_SCCOMMON connections
Name
IPARSET
BNO_WAIT_POS
BHOIST_MAN
BLOCKED_BIT0
BLOCKED_BIT1
BSLACKROPE
BBAYSCANNER_VALID
BLEARN_PROFILE_ON
BLEARN_PROFILE_RESET
BDIG_HOIST_DIST_CORR
BSAVE_LOGGER
BSTART_2D_CALC
BSPREADERS_COUPLED
BMAN_FIXOBST_OFF
BMAN_VAROBST_OFF
ILOAD
IVALUE_BAYSCANNER
ICOUNT_BAYSCANNER
IDS_WIDTH
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Type
Data
Unit-global variables of "AddOn"
type
IN
SINT
common_plc_parset
IN
BOOL
common_plc_no_wait_pos
IN
BOOL
common_plc_hoist_man
IN
BOOL
common_plc_locked_bit0
IN
BOOL
common_plc_locked_bit1
IN
BOOL
common_plc_slackrope
IN
BOOL
common_plc_bayscanner_valid
IN
BOOL
common_plc_learn_profile_on
IN
BOOL
common_plc_learn_profile_reset
IN
BOOL
common_plc_dig_hoist_dist_corr
IN
BOOL
common_plc_save_logger
IN
BOOL
common_plc_start_2D_calc
IN
BOOL
common_plc_spreaders_coupled
IN
BOOL
common_plc_man_fixobst_off
IN
BOOL
common_plc_man_varobst_off
IN
INT
common_plc_load
IN
DINT
common_plc_value_bayscanner
IN
DINT
common_plc_count_bayscanner
IN
INT
common_plc_ds_width
Overview of the software
3.3 Sway control function blocks
Meaning
Request Parameter set
Request, do not use waiting po‐
sition
Currently has no function
STS selected:
Locking state of the spreader
GSU selected:
Not relevant
STS selected:
Locking state of the spreader
GSU selected:
Not relevant
Slack rope
Selection of bay scanner
Request Learn height profile on
the waterside
Request Initialize height profile
on the waterside
Digital effective pendulum length
correction
Save logger files
Start of the 2D calculation
STS selected:
Spreaders coupled
GSU selected:
Not relevant
Consideration of fixed blocked
regions in manual mode
Consideration of variable
blocked regions in manual mode
Load [10 kg]
Bay scanner
Counter for bay scanner
STS selected:
Overall width in double-spreader
operation
GSU selected:
Not relevant
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics

Table of Contents