Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 72

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Overview of the software
3.3 Sway control function blocks
Task
The "FB_TargetsAddOnToPLC" block writes the Targets block to the PROFIBUS DP /
PROFINET PN output area.
Connections
The inputs must be connected using the unit-global variables of the "AddOn" MCC source file
with the outputs of the DCC_SCTARGETS DCC block.
Table 3-30
FB_TargetsAddOnToPLC connections
Name
bo_zsw1_Direction_Land
bo_zsw1_Direction_Water
bo_zsw1_Pos_Saved
i8Lane_Ship_Load_OK
i8Lane_Ship_Unload_OK
Targets_IO_PQW
72
Type
Data
Unit-global variables of "AddOn"
type
IN
BOOL
targets_sc_direction_land
IN
BOOL
targets_sc_direction_water
IN
BOOL
targets_sc_pos_saved
IN
SINT
targets_SC_Lane_Load_OK
IN
SINT
targets_SC_Lane_Unload_OK
OUT
ARRAY
addon_targets_send
[0..5] OF
word
Meaning
Bit 1 of status word 1
Bit 2 of status word 1
Bit 0 of status word 1
Return the lane number from
which the ship will be loaded
Return the lane number from
which the ship will be unloaded
Output array for the Targets
block (see Figure 5-13 Address
list in SCOUT (communication
between SIMATIC S7 and SIMO‐
TION) (Page 122))
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics