Fb_Hoistaddontoplc - Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Overview of the software
3.3 Sway control function blocks
Connections
The outputs must be connected using unit-global variables of the "AddOn" MCC source file with
the inputs of the DCC_SCHOIST DCC block.
Table 3-21
FB_HoistPLCToAddOn connections
Name
Hoist_IO_PIW
b16_stw1
bo_stw1_Release
bo_stw1_Travel
bo_stw1_OM_Pos
bo_stw1_OM_Speed
bo_stw1_OM_Hoist_Control
bo_stw1_LS_UP
bo_stw1_LS_DN
bo_stw1_PreLS_UP
bo_stw1_PreLS_DN
bo_stw1_Brake_closed
i16Override
i16Offset
3.3.2.4

FB_HoistAddOnToPLC

Symbol (FBD representation)
Figure 3-18
Task
The "FB_HoistAddOnToPLC" writes the Hoist block to the PROFIBUS DP / PROFINET PN
output area.
62
Type
Data type
Unit-global variables of "Ad‐
dOn"
IN
ARRAY
addon_hoist_receive
[0..5] OF
word
OUT
WORD
-
OUT
BOOL
hoist_plc_release
OUT
BOOL
hoist_plc_travel
OUT
BOOL
hoist_plc_om_pos
OUT
BOOL
hoist_plc_om_speed
OUT
BOOL
hoist_plc_om_hoist_control
OUT
BOOL
hoist_plc_ls_up
OUT
BOOL
hoist_plc_ls_dn
OUT
BOOL
hoist_plc_prels_up
OUT
BOOL
hoist_plc_prels_dn
OUT
BOOL
hoist_plc_brake_closed
OUT
INT
hoist_plc_override
OUT
INT
hoist_plc_offset
FB_HoistAddOnToPLC
Meaning
Input array for the Hoist block
(see Figure 5-13 Address list in
SCOUT (communication between
SIMATIC S7 and SIMOTION)
(Page 122))
Control word 1 output not separated
into individual bits
Bit 0 of control word 1
Bit 1 of control word 1
Bit 2 of control word 1
Bit 3 of control word 1
Bit 6 of control word 1
Bit 8 of control word 1
Bit 9 of control word 1
Bit 10 of control word 1
Bit 11 of control word 1
Bit 12 of control word 1
PLC override
Position offset from PLC
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics

Table of Contents