9.4.2

Commissioning the sway control system

9.4.2.1

Commissioning steps in the commissioning menu

Perform the commissioning steps in the commissioning menu. Call up the commissioning
menu using the "I" key from the main menu or from the display screens.
Figure 9-10
Start with commissioning step 1. Continue commissioning up to step 6. If a camera is in use, set
the communication addresses in step 6 before performing step 1.
Some parameters of the active parameter set are set automatically in these steps.
Note
Parameter sets must not be switched over while commissioning is in progress.
The successful completion of a commissioning step is indicated by a "+". After the
commissioning steps have been performed successfully, it is no longer necessary to set these
parameters manually.
Note
Certain steps may be omitted depending on the configuration.