Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 294

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

SIMOCRANE CeCOMM commissioning and diagnostic program
8.7 Diagram - trace function
Short name
Meaning
S_REF delayed
Position after the set delays
[TR]
V_REF delayed
Output velocity after the set delays
[TR]
Table 8-3
Analog signals, hoist
Short name
Meaning
V_SET [HO]
Hoist set velocity specified by the master switch
V_REF [HO]
Hoist set velocity using the set ramps
V_POS [HO]
Output velocity, hoist
V_ACT [HO]
Current hoist velocity
S_REF [HO]
Hoist set position
S_ACT [HO]
Hoist actual position
S_REF delayed
Position after the set delays
[HO]
V_REF delayed
Output velocity after the set delays
[HO]
In the lower section of the diagram user interface, the states of the input and output bits in the
PLC are displayed in the distance/velocity-time curve with a legend on the right-hand side.
Individual parameters or all parameters can also be selected in this legend.
Variable recordings
In addition to the "Values to be transferred" signals, four signal traces with variable selection are
available on each tab of the dialog box. In this way, a scalar signal can usually be selected that
is then recorded for the trolley and hoist. The list of signals can be found in Appendix A5
(Page 437).
Zoom
You can zoom areas of the diagram to view a more detailed display. To do this, click and drag
the mouse pointer (from the top left to the bottom right - rectangular form) over the area of
interest. Resize the rectangle in the opposite direction (zoom out) to restore the original display.
The axes can be scrolled and zoomed.
It is also possible to use the zoom function for the detailed view during the recording. Press the
space bar to leave the zoom again and continue monitoring the recording.
The "Zoom In" and "Zoom Out" function is also active in the lower diagram area for displaying
the states of the bits.
294
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Unit
mm
mm/s
Unit
mm/s
mm/s
mm/s
mm/s
mm
mm
mm
mm/s

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics

Table of Contents