Configuration
5.8 Copying MCC source files
5.8
Copying MCC source files
After the successful compilation, the "AddOn" and "Camera" MCC source files (STS only) can
be copied into the user project (with the Basic Technology).
①
②
Figure 5-19
①
②
Figure 5-20
After you have inserted the "Camera" MCC source file, you must adjust the IP address of the
camera. To do this, open the "Camera" MCC source file and set the start value of the
"camera_SC_Addr" parameter in the "Interface" in accordance with your configuration. If the
camera is connected via PROFINET, the address "0.0.0.0" must be entered.
126
User project
Application project
Copying the MCC source file in the application project
User project
Application project
Inserting an MCC source file in the user project
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA