Configuration; Requirement - Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Configuration

5.1

Requirement

Workable project
The precondition for installation of the AddOn technology is a workable project of the Basic
Technology [Ref 2] because every AddOn sway control corresponds to at least one version of
the Basic Technology (SIMOTION SCOUT version V5.2 SP1 or higher, SINAMICS version
V5.1 HF1 or higher, and SIMOCRANE Basic Technology version V3.0 or higher).
This can be checked as follows:
● Save and compile the project:
Click on the
● Consistency check via the shortcut menu of SIMOTION D 435-2 DP/PN, command "Check
consistency"
Note
When an electric drive is used for skew damping, the suitable TO/DO/MCC/DCC
(ActiveSkew_1) must also be copied from the project supplied (on DVD) and linked into the
execution system.
Either the hoist or the trolley can be used for linking, as the structure, the call, the
interconnection and the ON/OFF control are identical.
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
button in the display screen.