Alarm, error, and system messages
10.5 Error messages
Error
Bit No.
Brief description
E62
6
Start POS or SAM with excessive oscillation
E63
10
Damping factor reduced, trolley
E64
27
Velocity too high before blocked region
E65
-
Sway-control Off (start)
E66
-
Sway control only when stopping
E67
-
Controlled stop active
Table 10-6
TLS error (error double word 2)
Error
Bit No.
Brief description
E69
0 (32)
Failure rate of camera signal too large for skew damping
E70
1 (33)
Internal value range overflow
E71
2 (34)
Maximum values of internal variables reached
E72
3 (35)
Maximum position of skew axis exceeded
E73
4 (36)
Following error, skew axis
E74
5 (37)
Maximum values of internal physical variables reached
E75
6 (38)
Monitoring of oscillation amplitude
E76
-
Error in parameterization of position limits TLS
E77
7 (39)
Impermissible change to mode_comm
E78
8 (40)
Storage of the zero position not possible
E79
9 (41)
Following error, cylinder
E80
10 (42)
Additional mode selected in addition to cylinder jogging
E81
11 (43)
Maximum position of cylinder A exceeded
E82
12 (44)
Maximum position of cylinder B exceeded
E83
13 (45)
Maximum position of cylinder C exceeded
E84
14 (46)
Maximum position of cylinder D exceeded
Two values are shown in the bit number column. The value without parentheses is the number
of the bit in error word 2, and the value in parenthesis is the error bit number in relation to all
errors.
10.5.3.3

General and severe errors

E0 (Bit -/-) Cycle time too long
The cycle time is longer than 100 ms.
Error type:
Remedy:
376
Alarm
Add the DCC chart to a faster task.
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA