Advertisement

Bit no.
14
15
Note
Out, in, up, down refer to the Figure 7-4 Directions of movement (Page 240).
Table 3-14
Bit no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Table 3-15
Bit no.
0
1
2
3
4
5
6
7
8
9
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Name
Meaning
move_zero
Activate the TLS mode "go to zero positions"
as_on
Skew-damping On/Off
Control bits in control word 2
Name
Meaning
a_in_comm
Cylinder jogging: Retract cylinder A
b_in_comm
Cylinder jogging: Retract cylinder B
c_in_comm
Cylinder jogging: Retract cylinder C
d_in_comm
Cylinder jogging: Retract cylinder D
a_out_comm
Cylinder jogging: Extend cylinder A
b_out_comm
Cylinder jogging: Extend cylinder B
c_out_comm
Cylinder jogging: Extend cylinder C
d_out_comm
Cylinder jogging: Extend cylinder D
skewpos_ext
Set position for the skew drive is specified from an external source
SkA_in_comm
Move skew axis in
SkA_out_comm
Move skew axis out
move_SkA
Activate position control of electric skew drive
reset_mdl
Reset internal oscillation model
hold_trim_list
Hold the trim and list positions
-
Reserved
-
Reserved
Status bits in status word 1
Name
-
motion_terminated_SkA
zero
motion_terminated
skew_removed
-
-
-
a_out
b_out
Meaning
-
Motion terminated,
skew drive
Zero position reached
Motion terminated,
cylinder
Skew oscillation eliminated
Extend cylinder A
Extend cylinder B