Parameters
11.3 Hoist
P65 Waiting position, hoist
This parameter is used to define the waiting position for the hoist.
Default: 30000 [mm]
Access code: 0
P66 Minimum hoisting height, landside
Below the minimum hoisting height on the landside, only the hoist is operated when travel in
SAM mode starts; the trolley is operated afterwards. When lowering above the minimum
hoisting height, the hoist and trolley are moved up to this height when travel starts in SAM
mode. Below this height, only the hoist is operated. P66 is only operative in SAM mode.
Default: -200000 [mm]
Access code: 0
P67 Minimum hoisting height, waterside
Below the minimum hoisting height on the waterside, only the hoist is operated when travel
starts in semi-automatic mode. The trolley is operated afterwards. When lowering above the
minimum hoisting height, the hoist and trolley are moved up to this height when travel starts in
SAM mode. Below this height, only the hoist is operated. P67 is only operative in SAM mode.
Default: -200000 [mm]
Access code: 0
P68 Position for prelimit switch velocity, hoist, lifting
Position at which the hoist must have attained the prelimit switch velocity (P43). The position
at which the hoist is decelerated depends on the velocity (dynamic prelimit switches). The
parameter is only operative if P115 = 1.
Default: 0 [mm]
Access code: 0
P69 Maximum position for positioning, hoist
Larger target positions are not accepted and error E32 is triggered. If the hoist position is
outside the set limits in positioning mode, error E35 is triggered.
Default: 100000 [mm]
Access code: 0
404
min: -200000 [mm]
Display: Always
min: -200000 [mm]
Display: Only for STS (P102, selection 1 = ON)
min: -200000 [mm]
Display: Only for STS (P102, selection 1 = ON)
min: -200000 [mm]
Display: Always
min: -200000 [mm]
Display: Always
max: 200000 [mm]
max: 200000 [mm]
max: 200000 [mm]
max: 200000 [mm]
max: 200000 [mm]
SC integrated STS, GSU