Connections
The inputs must be connected using unit-global variables of the "AddOn" MCC source file with
the outputs of the DCC_SCHOIST DCC block.
Table 3-22
FB_HoistAddOnToPLC connections
Name
bo_zsw1_Ready
bo_zsw1_Active
bo_zsw1_Pos_Completed
bo_zsw1_Travel_UP
bo_zsw1_Travel_DN
bo_zsw1_Stop_At_Obst_MAN
Hoist_IO_PQW
3.3.2.5

FB_TrolleyPLCToAddOn

Symbol (FBD representation)
Figure 3-19
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Type
Data type
Unit-global variables of "Ad‐
dOn"
IN
BOOL
hoist_sc_ready
IN
BOOL
hoist_sc_active
IN
BOOL
hoist_sc_pos_completed
IN
BOOL
hoist_sc_travel_up
IN
BOOL
hoist_sc_travel_dn
IN
BOOL
hoist_sc_stop_at_obst_man
OUT
ARRAY
addon_hoist_send
[0..5] OF
word
FB_TrolleyPLCToAddOn
Overview of the software
3.3 Sway control function blocks
Meaning
Bit 0 of status word 1
Bit 1 of status word 1
Bit 2 of status word 1
Bit 4 of status word 1
Bit 5 of status word 1
Bit 8 of status word 1
Output array for the Hoist block
(see Figure 5-13 Address list in
SCOUT (communication between
SIMATIC S7 and SIMOTION)
(Page 122))
63