Figure 8-44
This is how logger files are generally displayed ONLINE. If a "Logger.bin" file is saved via
CeCOMM and if this is still stored on the memory card, <L-Load> can be used to load it into
CeCOMM. It is then displayed in this form. This function is only possible ONLINE and does not
apply to the files "Logger0.bin" to "Logger9.bin".  
The files "Logger0.bin" to "Logger9.bin" and the "Logger.bin" file which was copied to the hard
disk, can also be opened OFFLINE using the CeCOMM menu function "File" -> "Open".
8.9.3

Method of operation

Data modifications to a monitored variable are recorded and timestamped with the internal
clock of the SIMOTION system.
The display in SIMOCRANE CeCOMM shows the time stamp, name of the variable, and the
states "before" and "after" the change. Status changes of bits are shown in boldface type (see
Figure 8-45 Display of the logger content in SIMOCRANE CeCOMM (Page 314)).
Recording of obstacles in the logger
Obstacles are only written into the logger file if the TRAVEL control bit is set while semi-
automatic mode (SAM) is selected.
Monitoring obstacles for changes would accumulate data unnecessarily and essential
information could be lost as a result.
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
SIMOCRANE CeCOMM commissioning and diagnostic program
Online view of a logger file
8.9 Logger
311