Editing A Parameter Set; Changing A Parameter - Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

8.5.3.4

Editing a parameter set

"N" Edit another parameter set
Irrespective of the active parameter set, all current parameter sets can be edited with the "N"
key. The required number must be entered and confirmed with the "Enter" key. The selected
parameter set is displayed in the SIMOCRANE CeCOMM diagnostic program and can then
either be edited by pressing "C - Change parameter" or "Y - Copy parameter set." If no
parameter set is selected here then the relevant active parameter set can be edited upon
exiting the parameter menu.
Note
The parameter set selected with the "N" key can continue to be edited until the parameter menu
is exited again. Selecting the parameter menu again makes the parameter set selected via the
PLC interface editable again.
8.5.3.5

Changing a parameter

"C" Change parameters
The parameters of the active parameter set or of the parameter set previously selected by
pressing "N - Edit another parameter set" can be changed using the "C" function.
Note:
Changes to parameters P100-P102, P106 and P110 take effect in all parameter sets, otherwise
only in the parameter set that can be edited.
Once the "C" key is activated the parameter number must be entered (e.g. "1" for parameter P1)
and completed with the "Enter" key. The new value is then entered and confirmed twice with the
"Enter" key.
Changed parameters are marked with a "+" and a different font color in the displays ("1" ... "17").
Note
Each parameter changed in the active parameter set is effective immediately but is not stored
permanently. Changed parameters must also be saved permanently with "S" ("Save all
parameter sets"). All parameter sets are saved at all times.
Note
All parameters whose setting is not absolutely necessary during commissioning and which
were not therefore described explicitly in the appropriate sections should be left with their
default settings and only changed where required.
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
SIMOCRANE CeCOMM commissioning and diagnostic program
8.5 Monitor (tab)
285

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics

Table of Contents