Dcc_Scintpo - Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Overview of the software
3.3 Sway control function blocks
Bit no.
10
11
12
13
14
15
Error messages
If an error occurs in TLS control mode, the corresponding error bits and error numbers are set
by the block and displayed via SIMOCRANE CeCOMM.
Furthermore, the output "bError" is set at the DCC_SCCOMMON block and the error number
is output at output "IErrorID" (for a description and help, see Chapter Error list AddOn
(Page 374)). If several errors are present, the oldest error will be displayed.
3.3.1.7

DCC_SCINTPO

Symbol
Figure 3-12
Brief description
The block outputs the calculated interpolation points.
Method of operation
The number of interpolation points for the relevant movement in semi-automatic mode (SAM)
is issued at the output. Consecutive numbers (starting at 1) are assigned internally to the
interpolation points. The relevant hoist and trolley positions are issued at the output depending
on the specified interpolation point number.
52
Name
c_out
d_out
a_in
b_in
c_in
d_in
DCC_SCINTPO
Meaning
Extend cylinder C
Extend cylinder D
Retract cylinder A
Retract cylinder B
Retract cylinder C
Retract cylinder D
Operating Instructions, 07/2019, A5E48271265B AA
SC integrated STS, GSU