11.6 Camera measuring system/reflector

P115 Configuration of prelimit switches
Deceleration of the trolley and the hoist before the minimum or maximum position to prelimit
switch velocity. The dynamic prelimit switches (P24, P27, P64, P68) are enabled and disabled.
Meaning:
0
1
Default: #0
Access code: 1
P119 Lowering point in SAM travel from WS to LS
You will find more information in Chapter Influencing the lowering point in SAM travel from WS
to LS (Page 221).
0
1
Default: #0
Access code: 1
11.6
Camera measuring system/reflector
P120 Assignment of the camera measurement direction
Assignment of trolley travel direction to the measurement direction (x, y) of the camera.
Selection:
1
2
3
Default: #...
Access code: 1
Note
The directions specified refer to the camera image.
(See Chapter Commissioning steps in the commissioning menu (Page 331); Section "Set the
alignment of the camera (commissioning step 1)")
412
Dynamic prelimit switches deactivated, bits for prelimit switches active
Dynamic prelimit switches activated.
Display: Always
Fixed offset in the trolley direction (P26 + 2 * P106)
Internally calculated lowering point
Display: Always
Motion up or down corresponds to the trolley travel.
Motion to the left corresponds to the forward direction.
Motion up corresponds to the forward direction.
Display: Only for STS (P102, selection 1 = ON)
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA