Command Quick Reference
Command
:LOW <wvolt_type>,(@<ch_list>)
:LOW? (@<channel>)
MEMory
:VME
:ADDRess <mem_address>
:ADDRess?
:SIZE <mem_size>
:SIZE?
:STATe 1 | 0 | ON | OFF
:STATe?
OUTPut
:CURRent
:AMPLitude <amplitude>,(@<ch_list>)
:AMPLitude? (@<channel>)
:STATe ON | OFF,(@<ch_list>)
:STATe? (@<channel>)
:SHUNt ON | OFF,(@<ch_list>)
:SHUNt? (@<channel>)
:TTLTrg
:SOURce FTRigger | LIMit | SCPlugon | TRIGger
:SOURce?
:TTLTrg<n>
[:STATe] ON | OFF
[:STATe]?
:VOLTage
:AMPLitude <amplitude>,(@<ch_list>)
:AMPLitude? (@<channel>)
ROUTe
:SCAN LIST1 | LIST2 | LIST3 | LIST4 | LISTL
:SEQuence
:DEFine LIST1|LIST2|LIST3|LIST4|LISTL|ALL,(@<ch_list>) Specify order of channel measurements for Scan LISTn or all Scan Lists.
:POINts? LIST1 | LIST2 | LIST3 | LIST4 | LISTL
SAMPle
:TIMer LIST1 | LIST2 | LIST3 | LIST4 | LISTL | ALL,<interval>
:TIMer? LIST1 | LIST2 | LIST3 | LIST4 | LISTL
[SENSe:]
DATA
:CVTable? (@<ch_list>)
:RESet
:FIFO
[:ALL]?
:COUNt?
:HALF?
:HALF?
:MODE BLOCK | OVERwrite
:MODE?
:PART? <n_readings>
:RESet
FILTer
[:LPASs]
[:STATe] ON | OFF
[:STATe]?
286
HP E1313/E1413 Command Reference
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SCPI Command Quick Reference
Controls the connection of input LO on a Strain Bridge (Opt. 21 SCP).
Returns the LO connection for the Strain Bridge at channel.
Specify address of VME memory card to be used as reading storage.
Returns address of VME memory card.
Specify number of bytes of VME memory to be used to store readings.
Returns number of VME memory bytes allocate to reading storage.
Enable or disable reading storage in VME memory at
INITiate:IMMediate.
Returns state of VME memory, 1=enabled, 0=disabled.
Set the Current Source SCP channel to 488µA (MAX) or 30µA (MIN).
Returns the setting of the Current Source SCP channel.
Enable or disable the Current Source SCP channels.
Returns the state of the Current Source SCP channel.
Adds shunt resistance to leg of Bridge Completion SCP channels.
Returns the state of the shunt resistor on Bridge Completion SCP channel.
Sets the internal trigger source that can drive the VXIbus TTLTrg lines.
Returns the source of TTLTrg drive.
When module triggered, source a VXIbus trigger on TTLTrg<n>.
Returns whether the TTL trigger line specified by n is enabled.
Set the Strain Bridge excitation voltage (Option 21).
Returns the setting of the setting of excitation voltage on SCP.
Selects the Scan List to be used in the next measurement set.
Returns the number of points (channels) in Scan LISTn.
Sets the time interval in seconds between channel measurements for
Scan LISTn, or all four Scan Lists.
Returns the timer interval in seconds for Scan LISTn.
Returns elements of Current Value Table specified by ch_list.
Resets all entries in the Current Value Table to IEEE " Not-a-number" .
Fetch all readings until instrument returns to trigger idle state.
Returns the number of measurements in the FIFO buffer.
Returns 1 if at least 32,768 readings are in FIFO, else returns 0.
Fetch 32,768 readings (half the FIFO) when available.
Set FIFO mode.
Return the currently set FIFO mode.
Fetch n_readings from FIFO reading buffer when available.
Reset the FIFO counter to 0.
Enables/disables A/D's 12 KHz low-pass filter.
Returns the state of the A/D's low-pass filter.
Description