Input:filter[:Lpass][:State]; Input:filter[:Lpass][:State] <Enable>,(@<Ch_List>); Input:filter[:Lpass][:State]? (@<Channel>) - HP E1313A Manual

High speed a/d module
Table of Contents

Advertisement

INPut

INPut:FILTer[:LPASs][:STATe]

Parameters
Comments
Usage
INPut:FILTer[:LPASs][:STATe]?
Parameters
Comments
Usage
206
HP E1313/E1413 Command Reference
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
INPut:FILTer[:LPASs][:STATe] <
programmable filter SCP channel. When disabled (
are in their "pass through" mode and provide no filtering. When re-enabled
(
<
enable
>
=
ON
), the SCP channel reverts to its previously programmed setting.
Parameter
Parameter
Name
Type
<
enable
>
discrete (string)
ch_list
channel list (string)
<
>
If the SCP has not yet been programmed,
frequency.
This command will cause Error +3000, "illegal while initiated" if trigger is initiated.
*RST Condition:
ON
INP:FILT:LPAS:STAT ON,(@115,117)
INP:FILT:LPAS:STAT OFF,(@100:115)
INPut:FILTer[LPASs][:STATe]? (@<
filtering for the specified channel.
Parameter
Parameter
Name
Type
<
channel
>
channel list (string)
• <
channel
>
must specify a single channel only.
Returned Value: Numeric value either
The C-SCPI type returned is int16.
INP:FILT:LPAS:STAT? (@115)
INP:FILT? (@115)
enable
ch_list
enables or disables a
>,(@<
>)
<
enable
>
=
Range of
Values
ON | OFF
100 - 163
enables the SCP's default cutoff
ON
Channels 115 and 117 return to previously
set (or default) cutoff frequency.
Set channels 0 - 15 to "pass-through" state.
channel
>)
returns the currently set state of
Range of
Values
100 - 163
0
(off or " pass-through" ) or
Enter statement returns either 0 or 1.
Same as above.
OFF
), these channels
Default
Units
none
none
Default
Units
none
1
(on).
Chapter 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

E1413c

Table of Contents