HP E1313A Manual page 135

High speed a/d module
Table of Contents

Advertisement

134
Understanding the HP E1313/E1413
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Example Command Sequence
n
>,(@101,103,105,107) <n> can be 1 - 4.
ROUT:SEQ:DEF LIST<
SENS:FUNC:TEMP RTD,100,(@101,103)
SENS:FUNC:VOLT:DC (@105,107)
ROUT:SCAN LIST1
CALC:LIM:UPP:DATA 750,(@101,103)
CALC:LIM:LOW:DATA 450,(@101,103)
CALC:LIM:UPP:DATA .2,(@105,107)
CALC:LIM:LOW:DATA -.01,(@105,107)
CALC:LIM:STAT ON,(@101,103,105,107) Enable overall limit testing.
CALC:LIM:UPP:STAT ON,(@101,103,105,107)Enable upper limit testing.
CALC:LIM:LOW:STAT ON,(@101,103,105,107)Enable lower limit testing.
t
SAMP:TIM LIST1,<
>
c
TRIG:SOUR TIM
t
TRIG:TIM:PER <
>
p
TRIG:COUN <
count
>
ARM:SOUR <
source
>
INIT:IMM
Starting
ARM event, either hardware or software
Acquisition starts
Stopping
Stops when Trigger Count is reached unless count is INF then use ABORt.
100Ω RTD temperature channels
1 and 3.
Autorange voltage channels 5
and 7.
Default is autorange voltage.
Upper limit set to 750 °C.
Lower limit set to 450 °C.
Upper limit set to +.2VDC.
Lower limit set to -.01VDC.
<t
> can be 10µs to 32.768ms.
c
<t
> can be .1ms - 6.5536 s.
p
<count> can be 1 - 32768 or
INF.
<source> can be BUS, EXT,
HOLD, IMM, or TTLTrg0 -
TTLTrg7.