8.5 Output Control Commands

The output command subsystem is used to control the output state of the power source.
The following measurement commands are supported.
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
PRIMARY STAGES OFF
SECONDARY STAGES OFF
Figure 8-1: Energy Saving Modes and Output Commands State Diagram
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
OUTPut:FAST
Enable or disable fast energy savings startup mode (STANDBY mode)
when output is closed. This mode does not completely shut down all
inverters for energy savings while the output is off. This allows near
immediate application of output to the load when the output
command is received. When disabled, there is delay of 2.2 seconds to
allow all power stages to start up and settle in.
< 0 | OFF | 1 | ON >
<b>
OUTP:FAST ON
OUTPut:FAST?
<b>
OUTP:FAST?
1
OUTPut[:STATe]:ALL OFF
or
5 MINUTES if OUTP:FAST? = 1
SLEEP MODE
OUTPUT OFF
OUTPUT
ON
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
STANDY MODE
OUTPUT OFF
PRIMARY STAGES ON
SECONDARY STAGES ON
PRIMARY STAGES ON
SECONDARY STAGES OFF
Page 179 of 349