Query Format
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
STATus:QUEStionable:CONDition?
Queries the Questionable Status Condition Register.
<nr1>
STAT:QUES:COND?
0
STATus:QUEStionable:ENABle
Sets the content of the Questionable Status Enable Register.
0-32767
<nr1>
STAT:QUES:ENAB 255
STATus:QUEStionable:ENABle?
<nr1>
STAT:QUES:ENAB?
255
STATus:PRESet
The Status Preset command presets the Status Registers. The
Operational Status.
Enable Register is set to 0 and the Questionable Status Enable
Register is set to 0.
None
n/a
STAT:PRES
ADF SERIES™ OPERATION MANUAL