Pacific Power Source ADF Series Operation Manual page 201

Table of Contents

Advertisement

Query Format
Description
Examples
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
[SOURce:]VOLTage[:AC]#:LIMIT:SATuration:RANGe?
Returns the upper and lower limit sine wave RMS voltage at which
saturation of the output inverter will occur. Saturation limits are
determined in the maximum peak voltage capability of the AC
components at the output of the power source. For the ADF Series®,
these limits are -425Vp and +425Vp. The VOLT:AC1:LIM:SAT:RANG?
returns the min and max. RMS of a sine wave that may be
programmed.
Maximum allowable values are:
Maximum positive peak voltage:
V_peak_max = V_AC_peak_max
Minimum negative peak voltage:
V_peak_min = V_AC_peak_min
For a sinusoidal AC waveform, these limits are:
Vrms_sat =
(425
– Vdc) / 1.4142
Vrms_sat =
(-425
+ Vdc) / 1.4142
425 = 1.41 *
300 (V_AC_rms_sat =
<nr2>
VOLT:AC3:LIM:SAT:RANG?
300.5204
[SOURce:]VOLTage[:AC]#:LIMIT:SATuration:MAXimum?
Returns maximum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage[:AC]#:LIMIT:SATuration:RANGe? for details.
<nr2>
VOLT:AC3:LIM:SAT:MAX?
301.154
[SOURce:]VOLTage[:AC]#:LIMIT:SATuration:MINimum?
Returns minimum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage[:AC]#:LIMIT:SATuration:RANGe? for details.
<nr2>
VOLT:AC3:LIM:SAT:MIN?
0.000
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
300)
Page 201 of 349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents