Power Protection Programming Commands - Pacific Power Source ADF Series Operation Manual

Table of Contents

Advertisement

8.7.8

Power Protection Programming Commands

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
[SOURce:]POWer:LIMit#
This command sets the programmable true power limit level in kW
for phase #. If # is omitted, all available phases are set to the value
specified. The max available power for a phase can be obtained using
the [SOURce:]POWer:LIMit#:MAX? query command.
Limit value in kW
<nr2>
POW:LIM 2.5
[SOURce:]POWer:LIMit#?
<nr2>
POW:LIM1?
2.5000
[SOURce:]POWer:LIMit#:MAX?
Returns maximum available true power capability for the specified
phase # in kW. If # is omitted, returns maximum available power level
for last phase selected. Typically, this value will be the same for all
phases.
<nr2>
POW:LIM1:MAX?
5.0000
[SOURce:]POWer:PROTect:LEVel
This command sets the power protection trip level in kW for all
available phases. If the true power of any phase exceeds this trip
level, the power source will shut off the output to protect the load.
True power trip limit level in kW
<nr2>
POW:PROT:LEV 2.7555
[SOURce:]POWer:PROTect:LEVel?
<nr2>
POW:PROT:LEV?
2.7555
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 215 of 349

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADF Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents