Pacific Power Source ADF Series Operation Manual page 214

Table of Contents

Advertisement

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
[SOURce:]PROTect[:RMS]:CURRent:TDELAY <DELAY>
This command sets the rms current protection trip delay in 100
msecs increments, i.e. as setting of 5 means 500 msec.
< DELAY >
<nr1>
PROTect:CURR:TDELAY 5
[SOURce:]PROTect[:RMS]:CURRent:TDELAY?
<nr1>
PROT:CURR:LEV?
5
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:MINimum?
This command returns the minimum rms current protection trip
delay setting.
PROT:CURR:TDELAY:MIN?
0
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:MAXimum?
This command returns the maximum rms current protection trip
delay setting.
PROT:CURR:TDELAY:MAX?
3000
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:DEFault?
This command returns the default rms current protection trip delay
setting.
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:DEFault?
41.667
[SOURce:]PROTect[:RMS]:CURRent:TRIPped?
This command returns rms current protection trip status. Returns 1 if
tripped or 0 if not.
PROT:CURR:TRIP?
41.667
[SOURce:]PROTect[:RMS]:CURRent:TRIPped:CLEar
This command clears the rms current protection trip status. Once
cleared, the power source output can be enabled.
None
n/a
PROT:CURR:TRIP:CLE
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 214 of 349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents