Pacific Power Source ADF Series Operation Manual page 176

Table of Contents

Advertisement

Query Format
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Examples
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
MEASure:LOGger:STATe?
Returns the state of the measurement data logging process as a
number as follows:
0 – Stopped
1 – Running
2 – Paused
<nr1>
MEAS:LOG:STAT?
1
MEASure:LOGger:LIMit <cr>
Sets the number of samples to get. Once the logging process reach
this limit it will stop.If the limit is set as OFF or 0 it will not stop unless
MEAS:LOG:STOP is executed.
The limit can be specified as a number of samples or in seconds if a
character "S" is added to the number. If the limit is passed as
seconds, the command will compute the number of samples based
on the logging rate. The formula is: number of samples = seconds /
rate.
The rate can be set with:
MEASure:LOGger:RATE <nr1>
or queried with:
MEASure:LOGger:RATE?.
< OFF | 0 >
XS where X is a time limit in seconds
X where X is the limit in number of samples
<cr>
MEAS:LOG:LIM OFF
MEAS:LOG:LIM 20S
MEAS:LOG:LIM 100
MEASure:LOGger:LIMit?
0
MEAS:LOG:LIM?
10000
MEASure:LOGger:FILELimit <nr1>
Sets the limit of samples to save in the file. If the limit is reached and
the logging process continues, a new file will be created.
Limit in number of samples.
<nr1>
MEAS:LOG:FILEL 100
MEASure:LOGger:FILELimit?
<nr1>
MEAS:LOG:FILEL?
10000
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 176 of 349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents