SYSTem:AIO:INput[n]:GAIN <nr2>
Sets the full-scale gain of the ADF parameter controlled by the analog
input.
Full scale value
<nr2>
SYST:AIO:IN1:GAIN 230.0
SYSTem:AIO:INput[n]:GAIN?
<nr2>
SYST:AIO:IN1:GAIN?
230.00
SYSTem:AIO:INput[n]:GAIN:DEFault?
Returns the default full-scale gain for the specified analog input.
None
<nr2>
SYST:AIO:IN1:GAIN:DEF?
300.0
SYSTem:AIO:INput[n]:GAIN:MAXimum?
Returns the maximum full-scale gain for the specified analog input.
None
n/a
SYST:AIO:IN1:GAIN:MAX?
100000.000000
SYSTem:AIO:INput[n]:GAIN:MINimum?
Returns the minimum full-scale gain for the specified analog input.
None
n/a
SYST:AIO:IN1:GAIN:MIN?
-100000.000000
SYSTem:AIO:INput[n]:OFFSET <nr2>
Sets the offset of the ADF parameter controlled by the analog input.
Offset
<nr2>
SYST:AIO:IN1:OFFSET 50.0
SYSTem:AIO:INput[n]:OFFSET?
<nr2>
SYST:AIO:IN1:OFFSET?
15.00