SYSTem:AIO:OUTput[n]:CALibration:OFFset <nr2>
Calibrates the full scale gain of the ADF parameter controlled
by the analog output.
Reference
<nr2>
SYST:AIO:OUT1:CAL:OFF 0.01
SYSTem:AIO:OUTput[n]:CALibration:OFFset?
Returns calibration coefficient
<nr2>
SYST:AIO:OUT1:CAL:OFF?
0.010
SYSTem:AIO:OUTput[n]:CALibration:OFFset:DEFault?
Returns default calibration coefficient value
SYST:AIO:OUT1:CAL:OFF:DEF?
1.000
SYSTem:AIO:OUTput[n]:CALibration:OFFset:MAXimum?
Returns upper limit of calibration coefficient value
<nr2>
SYST:AIO:OUT1:CAL:OFF:MAX?
1.000
SYSTem:AIO:OUTput[n]:CALibration:OFFset:MINimum?
Returns lower limit of calibration coefficient value
<nr2>
SYST:AIO:OUT1:CAL:OFF:MIN?
1.000