Pacific Power Source ADF Series Operation Manual page 216

Table of Contents

Advertisement

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
[SOURce:]KVA:LIMit#
This command sets the programmable apparent power limit level in
kVA for phase #. If # is omitted, all available phases are set to the
value specified. The max available apparent power for a phase can be
obtained using the [SOURce:]KVA:LIMit#:MAX? query command.
Limit value in kVA
<nr2>
KVA:LIM 2.5
[SOURce:]KVA:LIMit#?
<nr2>
POW:LIM1?
2.5000
[SOURce:]KVA:LIMit#:MAX?
Returns maximum available apparent power capability for the
specified phase # in kVA. If # is omitted, returns maximum available
apparent power level for last phase selected. Typically, this value will
be the same for all phases.
<nr2>
KVA:LIM1:MAX?
5.0000
[SOURce:]MODE#?
Returns protection mode for the selected phase # (# = 1, 2, or 3). If #
is omitted, returns protection mode for all phases in comma
separated format.
Note: When the phase suffix is 1, 2 or 3 the possible return
categories are from 0 to 4. With suffix is omitted, this command will
return MIXED(5) if modes for each phase are not the same.
For example, if in split phase mode phase A (suffix 1) is in VOLTAGE
mode but phase B (suffix 2) is in CURRENT mode, the query
SOUR:MODE? you will return MIXED:
SOUR:MODE1? = VOLTAGE and SOUR:MODE2? = CURRENT ->
SOUR:MODE? = MIXED
If both or phases are set to the same mode, the actual mode will be
returned:
SOUR:MODE1? = VOLTAGE and SOUR:MODE2? = VOLTAGE ->
SOUR:MODE? = VOLTAGE
<cr>
Available protection modes:
0 = NONE
1 = VOLTAGE
2 = CURRENT
3 = POWER
4 = KVA
5 = MIXED
SOUR:MODE?
VOLTAGE, VOLTAGE, VOLTAGE
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 216 of 349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents