Pacific Power Source ADF Series Operation Manual page 200

Table of Contents

Advertisement

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
[SOURce:]VOLTage[:AC]#:SLEW
Sets AC voltage slew rate for phase # in Volts per msec. If # is
omitted, sets phase A slew rate to value specified.
Range 0.01 – 300.0
<nr2> and <nr3>
VOLT:AC1:SLEW 300.00
[SOURce:]VOLTage[:AC]#:SLEW?
Returns voltage slew rate setting for specified phase. If phase is
omitted, returns voltage setting for phase A.
<nr2>
VOLT:AC1:SLEW?
300.0000
[SOURce:]VOLTage[:AC]:LIMit:MINimum
Sets low user limit for AC voltage programming. User limits must fall
within actual hardware limits of the power source. Also, MIN limit
must be less than MAX limit.
0.000 – 300.000
<nr2>
VOLT:LIM:MIN 20.0
[SOURce:]VOLTage[:AC]#:LIMit:MINimum?
<nr2>
VOLT:LIM:MIN?
20.0000
[SOURce:]VOLTage[:AC]:LIMit:MAXimum
Sets high user limit for AC voltage programming. User limits must fall
within actual hardware limits of the power source. Also, MAX limit
must be greater than MIN limit.
0.000 – 300.000
<nr2>
VOLT:LIM:MAX 240.0
[SOURce:]VOLTage[:AC]#:LIMit:MAXimum?
<nr2>
VOLT:LIM:MAX?
240.0000
[SOURce:]VOLTage[:AC]#:LIMit:RANGe?
Returns available AC voltage range low and high limits.
<nr2>,<nr2>
VOLT:AC1:LIM:RANG?
0.0000,300.0000
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 200 of 349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents