Pacific Power Source ADF Series Operation Manual page 204

Table of Contents

Advertisement

Query Format
Description
Examples
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
[SOURce:]VOLTage:DC#:LIMit:SATuration:RANGe?
Returns maximum DC voltage at which saturation of the output
inverter will occur. Saturation limits are determined in the maximum
peak voltage capability of the AC+DC components at the output of
the power source. For the AFX Series®, these limits are -425 and
+425V. The VOLT:DC1:SAT? returns the max. DC level that may be
programmed based on the programmed AC wave shape and RMS
level.
Maximum allowable values are:
Maximum positive peak voltage:
V_DC = V_peak_max - V_AC_peak_max
Minimum negative peak voltage:
V_DC = V_peak_min + V_AC_peak_min
V_AC = 300Vrms sine wave
V_DC = 425 - 1.41 *
300
V_AC = 120Vrms sine wave
V_DC = 425 - 1.41 *
120
V_AC = 0Vrms
V_DC = 425 –
0
<nr2>
VOLT:DC1:LIM:SAT:RANG?
-225, + 225
[SOURce:]VOLTage:DC#:LIMit:SATuration:MAXimum?
Returns maximum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
<nr2>
VOLT:DC3:LIM:SAT:MAX?
254.946
[SOURce:]VOLTage:DC#:LIMit:SATuration:MINimum?
Returns minimum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
<nr2>
VOLT:DC3:LIM:SAT:MIN?
-254.946
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
(V_DC_sat =
0)
(V_DC_sat =
255)
(V_DC_sat =
425)
Page 204 of 349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents