Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
[SOURce:]CONFIG:HFreq <b>
This command enables high-frequency output current protection
extension mode. In this mode, the protection for high frequency
content at the output of the power source is held off for up to 2
seconds to allow short time events to ride through without tripping
the normal protection mode.
Note: Available in units with Firmware revision 1.6.6 or higher.
< 0 | OFF | 1 | ON >
<b>
SOUR:CONFIG:HF 1
[SOURce:]CONFIG:HFreq?
<b>
CONFIG:HF?
1
ADF SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
( 0 = Off, 1 = On)