ADF Series Power Source Operation Manual
SYSTem:DIO:INput[n]:FILtersize:MINimum?
Returns the minimum allowed filter size value.
<nr1>
SYST:DIO:IN1:FIL:MIN?
1
SYSTem:DIO:OUTput[n] <MODE>
Sets output value of digital output n. n = 1 or 2.
MODE The mode determines when an output is generated.
Available MODE settings are:
1, ON, 0, OFF it is used as general purpose output.
[ 0 | LOW | 1 | HIGH ]
OUTPUT_STATE indicates output enabled(1) or disabled(0).
FORM indicates single(1) or split/three(0).
FAULT indicates fault(1) or no fault(0).
TRANSIENT indicates when a transient is
running/paused/stepping(1) or stopped(0).
PROGRAM indicates when a program is in execution at
steady state level(1) or manual mode(0).
REMOTE indicates remote(1) or local(0) state
Defaults are:
OUTPUT1:
OUTPUT_STATE
OUTPUT2:
FORM
<cr>
SYST:DIO:OUT1 FAULT
SYSTem:DIO:OUTput[n]?
Returns settings for selected pin number n
<nr1>
SYST:DIO:OUT1?
OUTPUT STATE,NON-INVERTING
SYSTem:DIO:OUTput:CATalog?
Returns list of available digital outputs
<cr>
SYST:DIO:OUT:CAT?
COUPLING,FAULT,FORM,HIGH,LOW,OUTPUT
STATE,PROGRAM,REMOTE,TRANSIENT