Internal Mechanism Of K6Cm; Measuring And Monitoring By K6Cm - Omron K6CM User Manual

Motor condition
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

3 Measuring and monitoring System
3-1

Internal mechanism of K6CM

3-1-1

Measuring and monitoring by K6CM

What is Measuring?
After the power is turned ON, K6CM calculates measurement values every sampling period based on
the input from the sensor.
The calculation of the measurement value is executed inside the K6CM even before the trigger start,
and the measurement display is updated when the trigger is established.
This is called measuring.
What is Monitoring?
According to the trigger setting, K6CM performs threshold value judgment of the Warning/Critical level
for a measurement value, and then determines whether the measurement value is within the Warn-
ing/Critical level as an "individual alarm". Next, the OR logic is obtained for each "individual alarm" and
Normal/Warning/Critical is judged for each monitor target as the "Comprehensive alarm".
This is called monitoring. It displays the front LCD alarm bar of the K6CM device and performs transis-
tor output.
As shown in the figure, it is as follows.
Free run,
external trigger,
or internal trigger
Update
measurement
display
Measurement
Sensor
value A
Measurement
Sensor
value B
3 - 2
External trigger input
K6CM
Internal setting value
Individual alarm for each
Capture
measurement value
measurement value
Critical result
Critical
Warning
Warning result
Critical result
Critical
Warning
Warning result
Comprehensive
alarm output
as a device
Normal
OR logic of each
measurement
value
Warning failure
occurrence
Critical failure
occurrence
Self-diagnosis
error output
*1. It can be set to Normally open
K6CM Motor Condition Monitoring Device User's Manual (N219)
Software tool
PLC etc.
and/or
Ethernet
(EtherNet/IP or
Modbus TCP)
Alarm bar
Transistor Output
Output 1
Output 2
Output 3
ON
ON
Green
ON
OFF
Yellow
OFF
OFF
Red
Latch selection
N.O. is
available
selectable *1
OFF
LCD (Not lit.)
OFF
for Eip cpu version 1.10 or later
of the K6CM device and the
software tool version 1.1.0 or
higher.
ON
OFF

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6cm-ismK6cm-cimK6cm-vbmK6cm-ci2m

Table of Contents