8 Monitoring and Setting Using the EtherNet/IP Devices
*3. Transistor output method is a function implemented by version upgrade.
Eip cpu version: Implemented in the K6CM device with version 1.10 or higher. The Eip cpu version can be
confirmed by the following method.
• Confirm the description of the side label of the K6CM device
• Confirmation the read data using the software tool or message communications
*4. The monitoring delay time is a function implemented by version upgrade.
Eip cpu version: Implemented in the K6CM device with version 1.20 or higher. The Eip cpu version can be
confirmed by the method described in *3.
 Comprehensive current diagnosis type (K6CM-CI2M)
Attri-
Parameter
bute ID
name
6E hex
Current range
6F hex
Reserved
area
70 hex
Reserved
area
71 hex
Current fail-
ure warning
72 hex
Current fail-
ure critical
73 hex
Degradation
level 1 failure
warning
74 hex
Degradation
level 1 failure
critical
75 hex
Degradation
level 2 failure
warning
76 hex
Degradation
level 2 failure
critical
77 hex
Reserved
area
8 - 20
Description
Sets the current range.
0: 5 A
1: 25 A
2: 100 A
3: 200 A
4: 400 A
5: 600 A
Reserved area
Reserved area
Sets the current failure warning threshold.
0 to 9999
(Unit in the 5 A range: 0.01 A)
(Unit in other ranges: 0.1 A)
(0000 to 270F hex)
Sets the current failure critical threshold.
0 to 9999
(Unit in the 5 A range: 0.01 A)
(Unit in other ranges: 0.1 A)
(0000 to 270F hex)
Sets the degradation level 1 failure warning
threshold.
0 to 9999
(0000 to 270F hex)
Sets the degradation level 1 failure critical
threshold.
0 to 9999
(0000 to 270F hex)
Sets the degradation level 2 failure warning
threshold.
0 to 9999
(0000 to 270F hex)
Sets the degradation level 2 failure critical
threshold.
0 to 9999
(0000 to 270F hex)
Reserved area
K6CM Motor Condition Monitoring Device User's Manual (N219)
Data
Attri-
bute
Data type
Default value
Write
UINT
0003 hex
Write
UINT
0000 hex
Write
UINT
0000 hex
Write
UINT
07D0 hex
(2000)
Write
UINT
07D0 hex
(2000)
Write
UINT
001E hex
(30)
Write
UINT
0032 hex
(50)
Write
UINT
0014 hex
(20)
Write
UINT
0032 hex
(50)
Write
UINT
0000 hex

Advertisement