Tcp/Ip Interface Object (Class Id: F5 Hex) - Omron K6CM User Manual

Motor condition
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

8 Monitoring and Setting Using the EtherNet/IP Devices
Bit
10
Major Recoverable Fault
Vendor specific setting area
11
Major Unrecoverable Fault
Vendor specific setting area
12 to 15
Reserved area
8-3-6

TCP/IP Interface Object (Class ID: F5 hex)

This object is used to read and write settings such as the IP address, subnet mask, and default gate-
way.
Service Codes
Service code
01 hex
0E hex
10 hex
The data size is 96 bytes (by default) for Get_Attributes_All.
Class ID
Specify F5 hex.
Instance ID
Specify 01 hex.
Attribute ID
The attribute ID specifies the information to read.
 Class Attribute ID
The class attribute ID specifies the attribute of the object class.
Attribute ID
01 hex
Revision
8 - 26
Name
When the MS indicator matches conditions of the flashing red: True
When the MS indicator matches conditions of the flashing red: True
Always FALSE.
Service name
Get_Attributes_All
Get_Attribute_Single
Set_Attribute_Single
Parameter
Description
name
Revision of the object
Description
Description
Reads the values of all attri-
butes.
Reads the value of the speci-
fied attribute.
Writes the value to the speci-
fied attribute.
Attribute
Read
K6CM Motor Condition Monitoring Device User's Manual (N219)
Supported services
Classes
Instances
Not supported.
Supported.
Supported.
Supported.
Not supported.
Supported.
Data
Data type
Default value
UINT
0004 hex

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6cm-ismK6cm-cimK6cm-vbmK6cm-ci2m

Table of Contents