5 Installation and Wiring
3
Install the sensor head to the motor, and then connect to the pre-amplifier.
 Fixing the Vibration Sensor Head Using Adhesive
1
Make a flat surface of φ25 mm or more on the motor.
In general, bearings on the load side tend to malfunction, it is recommended to install it on the
load side bearing position.
Axis
Load side
2
Apply the adhesive thinly and evenly to both the adhesive attachment and the motor's flat sur-
face.
Adhesive attachment
Note The adhesive attachment is similar in shape to an easy-mounting magnet. Be careful not to handle
it by mistake.
5 - 10
Mating mark
Make a flat surface of φ25 mm or more on the shaft side upper part of the motor.
Bearing
Apply the adhesive thinly and evenly.
Remove rust and dirt such as oil of the flat.
Bearing
Three-phase
induction motor
K6CM Motor Condition Monitoring Device User's Manual (N219)
Motor's flat surface