Omron K6CM User Manual page 273

Motor condition
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

Insulation Resistance Sensor (Special ZCT (IRT))
 List of Models
Model
Construction
K6CM-ISZBI52
Split type
Note A cable for connection is provided with the ZCT (IRT).
 Ratings and Specifications
Item
Construction
Rated current
Diameter of through holes
Circuit topology
Power supply voltage
Rated voltage:
Voltage input terminal
Output terminal
Cable length
Recommended cable
Insulation resistance
Dielectric strength
Ambient operating temperature
Storage temperature
Ambient operating humidity
Degree of protection
Altitude
Applicable standards
Adaptive fuse
Installation environment
Weight
K6CM Motor Condition Monitoring Device User's Manual (N219)
Rated path
Rated voltage
current
300 A
200 to 480 VAC
Model
Indoor split type
300 A (When using the ground wire to penetrate)
52 mm dia.
Three-phase 3 wire, S-phase: ground
Three-phase four-wire, N-phase: grounding, load side: delta connection
Supplied from K6CM-ISM , DC 10 V (Direct current)
200 to 480 VAC, 50/60 Hz, three-phase
3-terminal lead wire L = 1 m
4-terminal lead wire L = 1 m
Voltage input: 1 m (can be extended up to 100 m)
Between ZCT (IRT) and K6CM device: 1 m (can be extended to 100 m)
Voltage input: STO/TC(CE) # 18×3C (manufactured by Chugoku Electric Wire & Cable
Co., Ltd.)
Between ZCT(IRT) and K6CM device: 2464C-S-CL3-2402P-B (manufactured by
Bando Densen Co., Ltd.)
Mounting bracket - Secondary winding: 100 MΩ min.
Mounting bracket - Secondary winding: 2.2 kV 1 min
-10 to 55°C (with no condensation or icing)
-20 to 65°C (with no condensation or icing)
25 to 85% RH
IP67 (IEC 60529)
2,000 m max.
Conforming standards:
EN61010-2-030
Installation environment: Pollution degree 2, overvoltage category II, measurement
category II
EMC: EN61326-1 (EMI: Class A EMS: Industrial Location)
Safety standards: UL61010-2-030 (Recognition) + CSA C22.2 No. 61010-2-030
Korean Radio Waves Act, RCM
1 A, 480 V, UL Listed, CSA Certified
Overvoltage category II, Measurement category II (CAT II, ZCT (IRT) input), Pollution
Degree 2 (EN 61010-1)
Approx. 2.3 kg (including cables)
Connected K6CM
Through hole dia (mm)
52 dia
Vibration & temperature
type (K6CM-ISM)
K6CM-ISZBI52
Appendices
device
A
A - 13