5-2-3
Installation of the Vibration & Temperature sensor
The pre-amplifier used for Vibration & temperature type (K6CM-VB) can be mounted on a DIN rail or
mounted on a wall with an M3 screw.
The mounting method is the same as K6CM device.
Vibration & temperature sensor
pre-amplifier
K6CM-VBS1
Installation of the Vibration Sensor Head
The vibration sensor head for Vibration & temperature type (K6CM-VB) should be mounted to the motor
to be monitored.
The pre-amplifier and the sensor head are removable, as they are connected with the Smartclick Con-
nector. Install the sensor head on the motor after it has been removed from the pre-amplifier.
K6CM Motor Condition Monitoring Device User's Manual (N219)
Mating mark
5 Installation and Wiring
Mounting with M3 screw
or
DIN Track mounting