Omron K6CM User Manual page 89

Motor condition
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

Individual monitoring status (common form of individual measurement value)
Bit posi-
tion
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
In the example of the status of [2018/3/5 7:25] in the log file example on the previous page, the charac-
ter string of the Main body status is "C200" and that of the individual monitoring status is "1000".
"C200" and "1000" are hexadecimal numbers, so convert them to binary numbers.
Main body status
Hexadeci
C
mal
Binary
1100
The bit positions are 15, 14, ... , 1, and 0 from the left.
In the above case, the Main body status 15th, 14th and 9th bits are all "1", so the measurement state is
"During monitoring" and Tr1 is "OFF" and both Tr2 and Tr3 are "ON".
Likewise for the individual monitoring status, the12th bit is "1", so the individual alarm result (Warning)
is "Alarm occurrence".
Note When the above status is "0001" or "0110" for example, the value displayed in the CSV file is like
"1" or "110" without the last "0".
K6CM Motor Condition Monitoring Device User's Manual (N219)
4 Introduction of the Motor condition monitoring Tool
Status
Present value unmeasured state
Present value input error
Reserved area
Reserved area
Maximum value unmeasured state
Maximum value input error
Reserved area
Reserved area
Minimum value unmeasured state
Minimum value input error
Reserved area
Reserved area
Individual alarm result (Warning)
Individual alarm result (Critical)
Reserved area
Reserved area
2
0
0
0010
0000
0000
Bit contents
0
Measured status
Unmeasured sta-
tus
Not occurred
Occurrence
Measured status
Unmeasured sta-
tus
Not occurred
Occurrence
Measured status
Unmeasured sta-
tus
Not occurred
Occurrence
No alarm
Alarm occurrence
No alarm
Alarm occurrence
Individual monitoring status
Hexadeci
1
0
mal
Binary
0001
0000
1
4
0
0
0000
0000