Omron K6CM User Manual page 215

Motor condition
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

 Instance Attribute ID
The instance attribute ID specifies the per-instance attribute.
Attri-
Parameter name
bute ID
01 hex
Vendor ID
02 hex
Device Type
03 hex
Product Code
04 hex
Revision
Major Revision
Minor Revision
05 hex
Status
06 hex
Serial Number
07 hex
Product Name
*1. Product Codes
Model name
K6CM-VBMx-EIP
K6CM-ISMx-EIP
K6CM-CI2Mx-EIP
The number of characters (0D hex) is added to the beginning of K6CM-VBM and K6CM-ISM.
The number of characters (0E hex) is added to the beginning of K6CM-CI2M.
*2. Status of the EtherNet/IP Port
Bit
0
Owned
1
Reserved area
2
Configured
3
Reserved area
4 to 7
Extended Device Status
Vendor specific setting area
8
Minor Recoverable Fault
Vendor specific setting area
9
Minor Unrecoverable Fault
Vendor specific setting area
K6CM Motor Condition Monitoring Device User's Manual (N219)
8 Monitoring and Setting Using the EtherNet/IP Devices
Description
Vendor ID
Device type
Product code
Device revision
Example: For Revision 1.01
Major Revision = 1
Minor revision = 1
Status of the built-in Ether-
Net/IP port
For details, refer to "Status of
the EtherNet/IP Port".
Serial number
Product name
Product Code
Product name (number of characters (1 byte) + character string)
1FC hex (508)
0D 4B 36 43 4D 2D 56 42 4D 78 2D 45 49 50
1FD hex (509)
0D 4B 36 43 4D 2D 49 53 4D 78 2D 45 49 50
1FF hex (511)
0E 4B 36 43 4D 2D 43 49 32 4D 78 2D 45 49 50
Name
Indicates when the built-in EtherNet/IP port has an open connection as the target
of a tag data link.
Always FALSE.
Tag data link settings exist.
0: Disable (no latch)
1: Enable (with latch)
Always FALSE.
Indicates the status of the built-in EtherNet/IP port.
0: Not used
1: Not used
2: One or more I/O connection failures
3: I/O connection is not established
4: Not used
5: Serious defect occurred (MS Criticality)
6: One or more I/O connections are established and one or more are in the RUN
state
7: One or more I/O connections are established and all are idle
8 to 15: Unused
Always FALSE.
Always FALSE.
Attri-
bute
Data type
Read
UINT
Read
UINT
Read
UINT
Read
Struct of
Read
USINT
Read
USINT
Read
WORD
*2
Read
UDINT
Read
SHORT_S
TRING
Description
Data
Default value
002F hex (Fixed value)
0303 hex (Fixed value)
For details, refer to
*1
"Product Codes".
- - -
Product specific
Product specific
- - -
Product specific
(Serial number)
Product specific
For details, refer to
*1
"Product Codes".
8 - 25
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6cm-ismK6cm-cimK6cm-vbmK6cm-ci2m

Table of Contents