Omron K6CM User Manual page 183

Motor condition
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

Monitor with the Transistor Outputs
When monitoring with the transistor outputs, the following monitoring is available.
Transistor
Transistor
Output 1
Output 2
*1
OFF
OFF
*1
*1
ON
ON
*1
*1
OFF
ON
*1
OFF
OFF
OFF
OFF
*1. This is the output result when "Transistor output method" is set to "Normally Close". By default, it is set to
"Normally Close". By setting it to "Normally Open" with the software tool or message communications,
ON/OFF can be reversed.
*2. When the trigger mode is "Free run", "MON" lights up.
Status display:
"MON": Monitoring in
progress
"ERR": Self-diagnosis
error
occurrence
K6CM Motor Condition Monitoring Device User's Manual (N219)
7 Monitoring with K6CM and Motor condition monitoring Tool
Transistor
Status
Output 3
display
ON
*1
*2
Not lit.
ON
"MON"
ON
ON
*1
OFF
"ERR"
Status
Monitoring Not yet
In the case of a trigger, monitoring is not started
yet after the power is turned ON.
Comprehensive
All measurement values
alarm: normal
are in normal condition.
Comprehensive
There is no "critical" in
alarm: Warning
the measurement value,
There is "warning" even if
at least one state.
Comprehensive
There is "critical" in even
alarm: Critical
one measurement value.
When the self-diag-
Self diagnostic error is occurring.
nosis error occurs
Terminal
Meaning
In the case that the transistor type is
Warning output
Normally Close,
Transistor
of comprehen-
ON: Comprehensive alarm is normal
Output 1 (+)
sive alarm.
OFF: Comprehensive alarm is warning or
Transistor output
critical
method can be
In the case that the transistor type is
set to Normally
Normally open,
Close or
Transistor
ON: Comprehensive alarm is warning or
Normally Open.
Output 1 (-)
critical
OFF: Comprehensive alarm is normal (* 3)
In the case that the transistor type is
Normally Close,
Critical output of
Transistor
comprehensive
ON: Comprehensive alarm is normal
Output 2 (+)
alarm.
OFF: Comprehensive alarm is warning or
Transistor output
critical
method can be
In the case that the transistor type is
Normally open,
set to Normally
Transistor
Close or
ON: Comprehensive alarm is warning or
Output 2 (-)
critical
Normally Open.
OFF: Comprehensive alarm is normal (* 3)
Self-diagnosis
Transistor
error output.
In the following cases, ON
Output 3 (+)
Transistor output
When self-diagnosis error does not occur
method is Normally
In the following cases, OFF
Transistor
Close, and can
When self-diagnosis error occurs
Output 3 (-)
not be changed.
*3.In either of the following cases, the transistor output
turns OFF regardless of the transistor output method.
• Monitoring is not performed (only when using the trigger
function)
• Self-diagnosis error occurrence
In addition, transistor output state (ON/OFF) is held at
the end of monitoring (only when using the trigger func-
tion)
Meaning
At the end of moni-
toring, the state of
transistor outputs 1
and 2 are retained
(only when using
the trigger func-
tion). "MON" will go
out at this time.
Operation
7 - 7
7