Omron K6CM User Manual page 87

Motor condition
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

Exten-
File type
sion
Log file
.csv
Automatic log file of monitored information.
It is used for graph display inside the tool.
It is CSV format, so it can be used by other applications.
File name: Project name _IIIIII_TT_YYYYMMDD_NNNN.csv
The contents of the file are as follows. One record consists of the following
two lines.
Line 1: [Device name], [Monitor type name]
From the second line: [Date and time], [Present value (PV)], [Threshold
(Warning)], [Threshold (Critical)], [Main body status], [Measurement status]
• Device name:
• Monitor type name:
• Date and time:
• Present value (PV), threshold (Warning), threshold (Critical):
• Main body status, measurement status:
Log file
.csv
Save timing:
• When saving the project.
• Every hour during monitoring
• When monitoring is completed
• When you select to save log files and project files at the end of the soft-
*1 The project is saved along with the log file. When log file is open, data is
*2 The maximum number of lines of the log file is 10,000 lines. If it exceeds
K6CM Motor Condition Monitoring Device User's Manual (N219)
4 Introduction of the Motor condition monitoring Tool
Description
IIIIII: Device ID (000000 to 999999)
TT: Monitor type (00 to 06)
00: acceleration, 01: velocity, 02: motor temperature,
03: temperature gap, 04: insulation resistance, 05: degradation level 1,
06: current, 07: degradation level 2
YYYY: Year
MM: Month (01 - 12)
DD: days (01 to 31)
NNNN: Serial number (the above-mentioned device ID, monitoring cate-
gory, number for identifying the same date year / month / date)
Any one of "K6CM_VB", "K6CM_IS", "K6CM_CI"
Any one of "acceleration", "velocity", "motor temperature", "temperature
gap", "insulation resistance", "current", "degradation level 1", "degradation
level 2"
A character string representing the date and time on the computer system
when monitoring
Monitoring form Character string expressing the present value (PV),
threshold value (Warning), threshold value (Critical) of K6CM device in
decimal number with decimal point
Monitoring form Character string in hexadecimal representation of each of
the 16 bits of the Main body status and measurement status of the K6CM
device (Refer to the next page for details on the CSV file content and sta-
tus)
ware tool
not saved. If you want to open the log file during monitoring, we recom-
mend copying it to another folder.
the maximum number of lines, create a new log file and save the log.
Save position by default
Directly under the folder of
the project file name | folder
of the motor name
Directly under the folder of
the project file name | folder
of the motor name
4 - 5
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6cm-ismK6cm-cimK6cm-vbmK6cm-ci2m

Table of Contents