Appendices
Select the K6CM series, and then click the middle
the connection in the tag data link.
Select the K6CM series displayed in the registered device list, click [New (N) ...] or dou-
ble-click the device, the Connection Allocation Dialog Box will be displayed.
The default values of each parameter are displayed, and then set the following items.
• Input tag set
Select the tag set name edited in "(1) -2. Editing tag set" from the drop down list and set it.
• Packet Interval (RPI)
From the setting range of K6CM (250 ms to 10000 ms), set the data send interval from
K6CM according to the system.
• Timeout Value
Select the timeout value at the occurrence of a communications error from the pull down
list and set it. The value can be set by multiple of packet interval (RPI). (4 times, 8 times,
16 times, ..., 512 times)
Additional Information
If detailed parameters (i.e., packet interval (RPI), timeout value) are not displayed, it can be dis-
played by clicking [Detail View].
A - 36
(Add device) Button to register
K6CM Motor Condition Monitoring Device User's Manual (N219)