6 POSITIONING CONTROL

6.22 Manual Pulse Generator Operation

[Control details]
Positioning control based on the number of pulses inputted from the manual pulse
generator is executed.
Simultaneous operation for 1 to 3 axes is possible with one manual pulse generator,
the number of connectable modules are shown below.
Number of connectable to the manual pulse generator
POINT
• When two or more Q173DPXs are installed, connect the manual pulse generator
to first (It counts from 0 slot of the main base) Q173DPX.
(When the manual pulse generator is used, only first Q173DPX is valid.)
(1) Positioning of the axis set in the manual pulse generator axis setting register
based on the pulse input from the manual pulse generator.
Manual pulse generator operation is only valid while the manual pulse generator
enable flag turn ON.
Manual pulse generator
connecting position
P1
P2
P3
(2) The travel value and output speed for positioning control based on the pulse input
from manual pulse generator are shown below.
(a) Travel value
The travel value based on the pulse input from a manual pulse generator is
calculated using the following formula.
[Travel value] = [Travel value per pulse]
pulse generator 1- pulse input magnification setting]
The travel value per pulse for manual pulse generator operation is shown
below.
Unit
mm
inch
degree
pulse
If units is [mm], the command travel value for input of one pulse is:
(0.1[ µ m])
(1[pulse])
setting)
3
Manual pulse generator
axis No. setting register
D714, D715
D716, D717
D718, D719
[Number of input pulses]
Travel value
0.1 [ µ m]
0.00001 [inch]
0.00001 [degree]
1 [pulse]
(Manual pulse generator 1- pulse input magnification
6 - 192
Manual pulse generator
enable flag
M2051
M2052
M2053
[Manual