Mitsubishi Electric MELSEC Q Series Programming Manual page 91

Motion controller, real mode
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3 POSITIONING DEDICATED SIGNALS
(a) The flag turns off if a speed change request occurs during deceleration to a
stop due to speed change "0".
V
ON
Start accept flag
OFF
(M2001+n)
Speed change "0"
OFF
accepting flag
(M2240+n)
(b) The flag turns off if a stop cause occurs after speed change "0" accept.
V
ON
Start accept flag
OFF
(M2001+n)
Speed change "0"
OFF
accepting flag
(M2240+n)
(c) The speed change "0" accepting flag (M2240+n) does not turn on if a speed
change "0" occurs after an automatic deceleration start.
V
ON
Start accept flag
OFF
(M2001+n)
Speed change "0"
accepting flag
OFF
(M2240+n)
Speed change "0"
V
1
Speed change V
ON
Speed change "0"
ON
Automatic deceleration start
3 - 42
2
V
2
Stop cause
Speed change "0"
t
t
t

Hide quick links: